How to Design an Esd Workstation

An ESD Workstation is a work area with materials and equipment that limit electrostatic voltages and ESD (electrostatic discharge) or more commonly referred to as Static.

The first step in protecting a workstation is to ground all components of the work area (work surfaces, people, equipment, etc.) to the same electrical ground point called the “common point ground.”

While it is recommended to take every precaution available to control static, not all the ESD steps below may be necessary for basic ESD protection. Your workstation may not require all these items. Call Transforming Technologies for help designing your ESD workstation

ESD Protection Steps

1. ESD Table Mat

A work surface that removes static from conductive items placed on it. Commonly made from durable materials such as rubber, vinyl or laminate. A 10mm grounding snap should be installed in the mat or every 10 ft if it is long.

2. Wrist Band and Coil Cord Set

Safely grounds a person working at a workstation.  It is worn around the wrist and is connected to ground through a long coiled cord and the common point ground.

3. Common Point Ground

Used for grounding ESD mats and provide a path-to-ground for the person wearing wrist straps.  It attaches to the ESD worksurface via the 10mm grounding snap.

 

4. ESD Floor Mat

ESD floor mats remove static charges from conductive items placed on it. ESD footwear such as a Heel Grounder must be worn to remove static from the person standing on the mat. It is best used for mobile personnel that cannot be tethered to one location by a wrist strap.   A grounding snap should be installed in the mat or every 10 ft if it is long.

5. ESD Floor Mat Ground Cord

Used for grounding the floor mat by providing a path-to-ground for an ESD floor mat.  Connects to the mat via a grounding snap.

6. ESD Heel Grounders

Worn on each shoe to connect a walking or standing person to ground.

7. Constant Monitors

These electronic devices continuously monitor the path to ground of a wrist strap, work surface and other grounded components on a workstation.  Eliminates the need to test wrist bands and protects against ground failures.

8. ESD Jackets

Provide shielding from static charges on your clothing. A “Hip-to-Cuff” grounding system ensures proper grounding without requiring wristbands being worn that can inhibit your movement.

9. ESD Equipment Testers

ESD wrist strap and heel grounders, like any equipment used every day, can wear. Ensure these items are in proper working order with ESD Equipment testers.

10. ESD Air Ionizers

Materials, called insulators, cannot be grounded by typical means.  Ideally insulators should be removed from the workstation, but if they must stay an ESD Air ionizer can neutralize static buildup.  Delivering a balanced stream of ionized air, ionizers remove static charges from insulating materials and isolated conductors.

Every situation is unique and requires different steps to properly manage a static situation.

Stationary Personnel

Mandatory Steps: 1,2,3

Suggested Steps: 7,9

Optional Steps: 4,5,6,7,10

Mobile Personnel

Mandatory Steps: 4,5,6

Suggested Steps: 9